DEVICES AND MEASUREMENT SYSTEMS


  • Search key
  • According to:
    • measured value
    • regulation
    • registry
    • interface
  • Extended device description
Maskotka z kluczem do poszukiwań..


The offered devices allow on: reading, registry and regulation of various climate parameters as well as few other values. The tables below can help in choosing the adequate device version. The following options, measured values, registry and regulation had been marked in the tables using the following abbreviations: 

  • A - analog (Pt - platinum thermo resistor, N - voltage),
  • D - differentiate air pressure,
  • G - toxic gases concentration,
  • I - other not mentioned,
  • K - wind direction,
  • L - output of the alarm level exceed signaling,
  • O - atmospheric precipitation,
  • P - air absolute pressure,
  • PC- PC computer as a cooperating device,
  • R - superficial conductance,
  • S - sun radiation,
  • T - air temperature,
  • Tr - various substance temperature (gases, liquids, solids),
  • V - wind speed,
  • W - air humidity,
  • Ws - solid body humidity,
  • Z(...) - measurement of the mentioned in the brackets values using outside measurement devices.
  • DEVICES AND MEASUREMENT SYSTEMS PRODUCED BY LAB-EL COMPANY
    TYPE MEASURED VALUE  REGULATION
    INSIDE REGISTRY  REGISTRY USING AN OUTSIDE DEVICE OUTPUT INTEFACE  COMMENTS
    LB-486 Z(T,W,P,D,K,
    V,S,G,O)
    no T,W,P,D,K,V,S,
    G,O
    PC RS-232, RS-485 4 outputs S300 + O
    LB-515 T no T PC RS-232 battery powered
    LB-520 T,W no T,W PC RS-232 battery powered
    LB-522 T,W no min/max no S300 battery powered
    LB-522T T no min/max no S300 battery powered
    LB-600 A, Z(T,W,P,D) A,T,W,P,D A,T,W,P,D PC RS-485 universal
    LB-701 + LB-702 T, W no T, W PC RS-232 battery powered
    LB-701 + LB-702B T, W, P no T, W, P PC RS-232 battery powered
    LB-701 + LB-704 T, W no no no no battery powered
    LB-701 + LB-705 T, W no T, W (PR version)  LB-731, LB-486, PC RS-232, S300
    LB-701 + LB-706 T, W no T, W PC RS-232 battery powered
    LB-701 + LB-706B T, W, P no T, W, P PC RS-232 battery powered
    LB-701 + LB-707(B)
    T, W, (P)
    no T, W, (P)
    PC
    RS-232, GPRS, SMS
    built-in GSM modem
    LB-701 + LB-725 T, W T, W T, W LB-731,LB-486, PC RS-232, S300  
    LB-701T + panel Tr according to panel
    in panel according to panel
    in panel panel as in the  LB-701
    LB-705 Z(T, W) no T, W LB-731, LB-486, PC RS-232, S300 a set with LB-701
    LB-706B Z(T,W), P no T, W, P PC RS-232 a set with LB-701
    LB-706T Z(T, W), A  no T, W PC RS-232 2 Pt inputs
    LB-707T Z(T, W), A
    no T, W, P
    PC
    RS-232, GPRS, SMS
    built-in GSM modem, 2 Pt inputs
    LB-708T T no no PC RS-232 2 Pt inputs
    LB-708TR T T no PC RS-232 1 Pt input
    LB-710 LB-710B
    LB-710D LB-710DB
    T, W z LB-722C no LB-731, LB-486, PC S300  
    LB-710R T, W z LB-722C no LB-741, LB-486, PC S300  
    LB-710L T, W z LB-722C no LB-731, LB-486, PC S300  
    LB-710NL T, W no no LB-732 LonWorks  
    LB-710T LB-710DT T, Tr z LB-722C no LB-731, LB-486, PC S300 1 Pt input
    LB-711 T, Tr z LB-724 no LB-741, LB-486, PC S300 8 Pt inputs
    LB-712TW T, W no no no 4..20mA, 
    0..1V, 0..10V
    analog outputs
    LB-715 T, W, P no no LB-755, LB-486, PC S300  
    LB-716 P z LB-724 no LB-731, LB-486, PC S300  
    LB-716D D z LB-724 no LB-731, LB-486, PC S300  
    LB-716P P z LB-724 no LB-731, LB-486, PC S300
    LB-720 T, W T, W W LB-731, LB-486, PC S300  
    LB-720C T, W T, W, L 1 value
    LB-731, LB-486, PC S300
    LB-724 Z(T,W,P,D,K,
    V,S,G,O)
    T,W,...,L 1 value
    LB-731, LB-486, PC S300 1 input S300
    LB-725 Z(T, W) T, W T, W LB-731, LB-486, PC RS-232, S300 a set with LB-701
    LB-731 Z(T, W, P, D) L T, W, P, D PC RS-232, S300 16 inputs S300
    LB-732 Z(T, W, P, D) L T, W, P, D PC RS-232, RS-485,
    LonWorks
     
    LB-741 Z(T,W,P,D,K,
    V,S,G,O)
    no T,W,P,D,K,V,S,
    G,O
    PC RS-232, RS-485 8 inputs S300 + O
    LB-746 K, V no no LB-741, LB-486, PC S300  
    LB-747 K, V no no LB-741, LB-486, PC S300
    LB-750 P no P LB-731, LB-486, PC RS-232, S300
    LB-754J + LB-706T T no T PC RS-232 battery powered, thermometer
    LB-754T + LB-706T T (2x) no T PC RS-232 bateryjny, 2 thermometers
    LB-754T + LB-707T T
    no T
    PC
    RS-232, SMS, GPRS
    built-in GSM modem
    LB-754P + LB-706T T, W no T, W PC RS-232 psychrometer
    LB-755 Z(T, W, P, K,
    V)
    no T, W, P, K, V PC RS-232  
    LB-756 Z(S ) no S PC RS-232  
    LB-760A T, W, Z(G) T, W, G, L T, W, G, I PC RS-485 8 Pt inputs
    LB-781 R, T no no LB-741, LB-486, PC S300  
    LB-790 Ws (sand) no Ws LB-741, LB-486, PC RS-232  
    LB-795 Ws (wood, concrete) no yes PC RS-232 3 measurement methods
    LB-810
    (water flow)
    I I LB-741, LB-486, PC S300  
    LB-810W I
    (water level)
    I I LB-741, LB-486, PC S300  
    LB-900 S no no LB-741, LB-486, PC S300  
    LB-910 R no no LB-741, LB-486, PC S300  
    Meteo w internecie Z(T,W,P,K,V,
    S,O)
    no T,W,P,K,V,S,O PC Internet  
    DEVICES AND MEASUREMENT SYSTEMS PRODUCED BY OTHER COMPANIES
    TYPE MEASURED VALUE  REGULATION
    INSIDE
    REGISTRY 
    REGISTRY USING
    AN OUTSIDE DEVICE 
    OUTPUT INTEFACE COMMENTS
    ZFP9 G (CO2) no no LB-760, LB-760A 4..20 mA
    2 x transmitter 
    IR detection  
    373 W no yes
    PC RS-232, 
    0..1V, 4..20mA
    humidity standard  
    ARG100 O no no LB-486, LB-724, LB-741 reed relay  
    DP19 W no no PC RS-232 humidity standard  
    DP30 W no no PC RS-232 humidity standard  
    EBI-A T, P no T, P PC RS-232 battery powered
    Kestrel 2000 V, T no V (Max) no no battery powered
    RG50 O no no LB-486, LB-724, LB-741 reed relay  
    Elektronika Laboratoryjna Produced by: LAB-EL Laboratory Electronics
    68b, Bodycha Str., 02-495 Warsaw
    tel: (022) 667 71 18, 0601 209656, fax: (022) 867 53 32
    e mail: info@label.com.pl
    home page: http://www.label.com.pl
    internet meteorological station: http://www.meteo.waw.pl
    meteorological station on a mobile phone: wap.meteo.waw.pl