LABEL-LB487-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, enterprises, Opaque FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC; lb487 MODULE-IDENTITY LAST-UPDATED "200706160831Z" ORGANIZATION "LAB-EL Elektronika Laboratoryjna" CONTACT-INFO "www: http://www.label.pl email: info@label.pl phone: +48 22 7536130 address: Herbaciana 9 05-816 Reguly Poland" DESCRIPTION "MIB module for LAB-EL LB-487 data acquisition module" REVISION "200706160831Z" DESCRIPTION "Initial version" REVISION "201103031831Z" DESCRIPTION "General overhaul." ::= { label 487 } label OBJECT IDENTIFIER ::= { enterprises 22925 } -- device information deviceInfo OBJECT IDENTIFIER ::= { lb487 1 } deviceInfoSerialNumber OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS current DESCRIPTION "Device serial number." ::= { deviceInfo 1 } -- input info table inputTable OBJECT-TYPE SYNTAX SEQUENCE OF InputEntry ACCESS not-accessible STATUS current DESCRIPTION "Table of input data information." ::= { lb487 2 } inputEntry OBJECT-TYPE SYNTAX InputEntry ACCESS not-accessible STATUS current DESCRIPTION "Entry in input data table." INDEX { inputIndex } ::= { inputTable 1 } InputEntry ::= SEQUENCE { inputIndex INTEGER, inputMode INTEGER } inputIndex OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS not-accessible STATUS current DESCRIPTION "Input data table index." ::= { inputEntry 1 } inputMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Input mode: 0 - off (not used), 1 - calibration, 2 - S300, 3 - 0-10V, 4 - 0-20mA, 5 - thermometer, 6 - binary (bool), 7 - safe switch, 8 - impulse counter, 9 - analog: 0-10V scaled, 10 - analog: 0-20mA scaled." ::= { inputEntry 2 } -- measurement results resultTable OBJECT-TYPE SYNTAX SEQUENCE OF ResultEntry ACCESS not-accessible STATUS current DESCRIPTION "Table of measurement results." ::= { lb487 3 } resultEntry OBJECT-TYPE SYNTAX ResultEntry ACCESS not-accessible STATUS current DESCRIPTION "Entry in results table." INDEX { resultInputIndex, resultVarIndex } ::= { resultTable 1 } ResultEntry ::= SEQUENCE { resultInputIndex INTEGER, resultVarIndex INTEGER, resultFixedPoint INTEGER, } resultInputIndex OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS not-accessible STATUS current DESCRIPTION "Result table input index." ::= { resultEntry 1 } resultVarIndex OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS not-accessible STATUS current DESCRIPTION "Result table variable index." ::= { resultEntry 2 } resultFixedPoint OBJECT-TYPE SYNTAX INTEGER (-32768..32767) ACCESS read-only STATUS current DESCRIPTION "Measurement result represented as fixed point. Decimal dot is just skipped, so 12.3 is 123. Missing data returns special value -32768. Sensor failure returns special value 32767." ::= { resultEntry 3 } -- s300 info table s300Table OBJECT-TYPE SYNTAX SEQUENCE OF S300Entry ACCESS not-accessible STATUS current DESCRIPTION "Table of S300 sensor information." ::= { lb487 4 } s300Entry OBJECT-TYPE SYNTAX S300Entry ACCESS not-accessible STATUS current DESCRIPTION "Entry in S300 info table." INDEX { s300Index } ::= { s300Table 1 } S300Entry ::= SEQUENCE { s300Index INTEGER, s300Type INTEGER, s300SerialNumber INTEGER } s300Index OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS not-accessible STATUS current DESCRIPTION "S300 info table index." ::= { s300Entry 1 } s300Type OBJECT-TYPE SYNTAX ITEGER ACCESS read-only STATUS current DESCRIPTION "S300 device type: 0 - no sensor, 1 - LB-710, 2 - LB-711, 3 - LB-715, 4 - LB-716, 5 - LB-756, 6 - LB-900, 7 - LB-901, 8 - LB-905, 9 - LB-910, 10 - LB-920, 11 - LB-850, 12 - LB-710T, 13 - LB-710E." ::= { s300Entry 2 } s300SerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "S300 device serial number. Valid only when sensor type != 0." ::= { s300Entry 3 } END