HYGROMETER and/or THERMOMETER LB-712TW
|
![]() |
Description
Hytherograph LB-712TW is designed for air temperature and relative humidity measurement. It can work in places where there is great dustiness, since it has a hermetic casing and an adequate filter, which protects the measurement sensors. It is a stationary device of small size, powered from an outside power supply.
The device consists of two totally electrically independent parts: a thermometer and a hygrometer (humidity meter). The only thing that connects those two parts of the device is a shared construction plate and a casing. Each one of those parts can be made in three versions: with a digital current loop 4..20mA (I), with a voltage output 0..1V (N1) or with a voltage output 0..10V (N10). Additionally a hygrometer can be custom made for standard scope of humidity measurement 10..95% or for an extended scope 0..100% (H). The thermometer can be made with a temperature sensor placed in a casing (standard version) or with a temperature sensor made in a form of an external probe (LB-712TZ), two or four cable (in this case it has to be only a thermometer without a hygrometer). There are also possible other versions of the device: a hygrometer (LB-712W) or a thermometer (LB-712T). The device's output measurement signal is made in a form of screw terminals that are placed inside of the casing to which a cable is attached using a whole of 7 mm in diameter. In the version LB-712Y the device has a SzR14 type connection.
Hytherograph LB-712 can be made in a special "S" version (in a silicone filing compound), equipped with a silicone casing screen type F4, what makes the electronic system resistant to high humidity. Independently from the ("S") type version the device cannot be exposed to direct precipitation and out dropping water vapor. That is why in the open space conditions it is recommended that it should be placed (i.e. in a meteorological cage).
Except from the analogous measurement result output the construction of the main part of the device is digital and based on an efficient and energy saving microprocessor controller. The device's standard version is adapted for short time (up to few hours) measurements on the ends of measurement scopes, except from that the device should stay in the recommended constant work conditions. The device in a standard version is equipped with a sensor shield (pollution filter) type F3.
Hytherograph LB-712TW is calibrated in a climate chamber and the
calibration data from the humidity and temperature sensors is stored in
a digital nonvolatile memory of the device and is used during
measurements for calculating of the final results. The calculations
made by the device's microprocessor are made very precisely and take
into consideration the nonlinear measurement characteristics of the
humidity and temperature sensors.The calculations take under
consideration the calibration data from the output voltage
converter or the current loop.
The main features that distinguish the device are as follow:
- wide scope of work temperatures (-40°C ..+85°C),
- precise, numeric measurement procedure,
- possibility of numerous calibrations through a RS-232C interface (lack of regulation elements, i.e. potentiometers),
- wide scope of power supply voltage,
- power supply line is common with the output current loop line
(for version 4-20 mA).
Technical data
| TEMPERATURE MEASUREMENT | ||
|---|---|---|
| Measurement inaccuracy |
+/- 0.3°C | |
| Scope of measurement |
-40..+85°C | |
| -100..+200°C | for LB-712TZ, programmed scope, external probe |
|
| Measurement resolution |
+/- 0,1% | programmable measurement scope |
| HUMIDITY MEASUREMENT |
||
|---|---|---|
| Measurement inaccuracy |
+/- 2.5% | in the scope of 10...90% |
| +/- 4.5% | outside of the scope 10...90% | |
| Scope of measurement LB-712 | 10..95% | for temperatures up to +40°C |
| 10..60% | for temperatures up to +70°C | |
| 10..40% | for temperatures up to +85°C | |
| Measurement resolution |
+/- 0,2% | |
| ANALOG OUTPUTS | |||||
|---|---|---|---|---|---|
| version | output | for 0% RH (or for the beginning of a thermometer range) |
for 100% RH (or the end of a thermometer range) |
power supply voltage |
energy consumption |
| LB-712 | current loop |
4 mA | 20 mA | 10..29V DC | max. 20mA |
| LB-712N1 | voltage | 0 V | 1 V | 10..29V DC | max. 3mA |
| LB-712N10 | voltage | 0 V | 10 V | 17..29V DC | max. 10mA |
| RECOMMENDED CONSTANT WORK CONDITIONS *) | |
|---|---|
| Scope of temperatures |
0..40°C |
| Scope of humidity | 20..80% |
| Level of environment corrosion aggressiveness accord.
PN-71/H-04651 |
B |
| Level of casing protection |
IP 65 limited additionally by the class of filter protection |
CALIBRATION INTERFACE
Standard RS-232C, transmission speed 30 bits/s, 7 information bits, 1 start bit and 1 bit stop.OVERALL DIMENSIONS
Approximately 170 x 64 x 35 mm (overall dimensions with pulled out protection shield and with a pass).EXTENDED VERSIONS
![]() LB-712Z with a connection SzR14 |
- LB-712S - with greater resistance to climate conditions (in a silicone filling),
- LB-712Fn - sensor protection version (according to a
description), the version is given
if it is different than F3, - LB-712Z - with an addition connection SzR14 (instead of the terminals inside of the casing).
DETAILED QUALITY OF WORK DENOTATION
Various versions of the device LB-712TW have the following detailed descriptions:LB-712 T/aaa/zp/zk/W/bbb/c
- LB-712 - device name,
- T- beginning of the field thermometer version,
- aaa - thermometer version: I - current loop
4..20mA, N1 - voltage output 0..1V, N10 - voltage output 0..10V,
- zp -beginning of the thermometer measurement scope,
- zk - end of the thermometer measurement scope,
- W - beginning of the hygrometer field version,
- bbb - hygrometer version: I - current loop 4..20mA, N1 - voltage output 0..1V, N10 - voltage output 0..10V,
- c - optional characters that can appear at the end of a symbol, if the quality of work is different than a standard (standard quality of work: internal sensors, F3 shield, scope of humidity measurement 10..95%, output line clips inside a casing, lack of silicone filing) then those characters can take the following values:
- S - special version with a silicone filling,
- H - extended scope of humidity measurement from 0 to 100%,
- Fn - sensors shield version, version is provided
if it is different than F3,
- X - external probe for temperature measurement PT1000 (an external probe is only available for LB-712T),
- U - external probe for temperature measurement Pt100 (an external probe is only available for LB-712T),
- Z - with a terminal connection SzR14 (instead of
clips inside a casing) see picture.
- LB-712 T/I/W/I - both a thermometer and a hygrometer in a current version, thermometer with and an internal sensor, a hygrometer for standard scope of humidity measurement 10 .. 95%.
- LB-712 T/I/W/N10/S - a thermometer with a current output and an internal sensor, a hygrometer with a voltage output 0..10V in a silicone filling.
- LB-712 W/N1 - only a hygrometer with a standard scope of
humidity measurement and a voltage output 0..1V.
Example:
- LB-712 T/IZ/-10/+20/X, 4 conductors of cable, cable length 10m, probe length 10cm, diameter 6mm - LB-712 specification with: current output, scope of measurement from -10 to +20°C,external probe for temperature measurement and a detailed description of the external probe construction.